Category: Accessories
Showing 1–16 of 34 results
-
auto::blade
Mechanical Cleaning for spectrometer probes with path length 5 mm Mounting on F-48-V3 wastewater flow cell Exchangeable wiper blades Set of cleaning and valve unit Technical Specification Power Supply: 12 VDC Power consumption (typical): 200 mA Cable length: 1,5 m Tube length: 1,5 m Housing… -
ruck::sack
The ruck::sack is an attachment for spectrometer probes and for the i::scan with submersible autobrush and also with exchangeable cleaning brushes Submersible Autobrush for spectrometer probes and i::scan Exchangeble brushes for spectrometer probe with path length 35, 15, 5 mm and i::scan 35, 5 mm One Basis module (motor unit)… -
s::can compressor
provides compressed air for s::can spectrometer probes, oxi::lyser, soli::lyser and ammo::lyser™ removal of fouling using compressed air aluminium housing IP65 for wall mounting optional 12 VDC or 110 VAC version available railing-mounting set available technical specification power supply:… -
i::scan carrier
for easy attachment of one i::scan technical specification housing material: PVC, POM-C dimensions (diameter x lenght): 58 x 115 (without connection fitting) installation / mounting: submersed part numbers F-110-iscan: carrier for i::scan, for easy horizontal attachment F-120-iscan: carrier for i::scan, for easy vertical… -
flow cell for sensors (waste water)
For proper and easy installation of s::can sensors (pH::lyser, redo::lyser or condu::lyser) in waste water technical specification housing material: PVC dimensions : 177 x 95 x 111 mm Part Number: F-48-sensor Datasheet flow cell for sensors… -
single flow-cell (by-pass fitting), Pom-C (for i::scan)
for proper and easy flow-through installation of one i::scan automatic cleaning with autobrush for i::scan available (optional) technical specification housing material: POM-C dimensions (diameter x length): 70 x 86 process connection: G 1/4″, hose nozzle 7mm installation / mounting: flow cell operating temperature:… -
flow cell – for pathlength 100 mm
the flow cell is used for proper and easy flow-through installation of s::can spectrometer probes for applications without automatic cleaning OPL 100 mm technical specification housing material: POM-C dimensions (diameter x length): 60 x 160 mm weight (min.): 300 g process connection: G 1/4”, hose… -
Pressure mounting for i::scan in-pipe Installation (i::scan removal under pressure)
for proper and easy installation of one i::scan in a pressure pipe under pressure drilling of pipes possible (for PE, PVC, DCI, steel and AC pipes) the i::scan can be mounted and demounted under pressure without interuption of the water flow technical specification housing… -
flow cell for i::scan (waste water)
Flow cell for proper and easy flow-through installation of one i::scan in waste water application technical specifications housing material: PVC dimensions (lenght x width x height): 177 x 83 x 90 mm process connection: 1″ inside thread installation / mounting: flow cell recommended flow:… -
flow cell autobrush – for spectro::lyser pathlength 100 mm
for proper and easy flow-through installation of s::can spectrometer probes for applications with frequent, automatic cleaning cleaning of optical windows with rotating brush without demounting of spectrometer probes OPL 100 mm technical specification power supply: 12 VDC assembling: ex works… -
fixing adapter – stainless steel
supports the proper and easy installation of s::can systems quick mounting and demounting of InSitu installed s::can probes and sensors technical specification housing material: stainless steel weight (min.): 2.6 kg process connection: ID 50 mm part number: F-15 recommended accessories F-14-3 mounting… -
cleaning valve
supports automatic cleaning of measuring elements of s::can spectrometer probes, oxi::lyser, soli::lyser and ammo::lyser™ removal of fouling, sediments and clogging using compressed air or water version B-44-2 specially for use in comination with the s::can compressor technical specification cable length: 2.4 m (B-44);… -
cleaning brush
supports quick, easy and proper cleaning of optical windows of s::can spectrometer probes mechanical removal of persistent window fouling for pathlength 2, 5 or 15 mm technical specification dimensions (diameter x length): length 200 mm weight (min.): 1 g part number: B-60-1 for 2… -
cleaning agent
supports quick, easy and proper cleaning of optical windows of s::can spectrometer probes chemical removal of persistent window fouling very effective for grease and organic fouling technical specification weight (min.): 1.3 kg part number: B-61-1… -
flow cell autobrush – for spectro::lyser pathlength 35 mm
for proper and easy flow-through installation of s::can spectrometer probes for applications with frequent, automatic cleaning cleaning of optical windows with rotating brush without demounting of spectrometer probe OPL 35 mm technical specification power supply: 12 VDC assembling: ex works housing material: POM-C… -
s::can field case
stand-alone operation of s::can spectrometer probes no on-site power supply necessary for remote monitoring tasks without infrastructure technical specification power supply: 12 VDC nominal assembling: ex works housing material: PP dimensions (width x height x depth): 270 x 175 x 245 mm…