With this selection of s::can Asseccoirs, you will find exactly what you need to get the most out of your system. From flow cells and cables to the right electrodes – here are all s::can Asseccoirs.
Accessories
Accessories
-
auto::blade
Mechanical Cleaning for spectrometer probes with path length 5 mm Mounting on F-48-V3 wastewater flow cell Exchangeable wiper blades Set of cleaning and valve unit Technical Specification Power Supply: 12 VDC Power consumption (typical): 200 mA Cable length: 1,5 m Tube length: 1,5 m Housing… -
ruck::sack
The ruck::sack is an attachment for spectrometer probes and for the i::scan with submersible autobrush and also with exchangeable cleaning brushes Submersible Autobrush for spectrometer probes and i::scan Exchangeble brushes for spectrometer probe with path length 35, 15, 5 mm and i::scan 35, 5 mm One Basis module (motor unit)… -
s::can compressor
provides compressed air for s::can spectrometer probes, oxi::lyser, soli::lyser and ammo::lyser™ removal of fouling using compressed air aluminium housing IP65 for wall mounting optional 12 VDC or 110 VAC version available railing-mounting set available technical specification power supply:… -
i::scan carrier
for easy attachment of one i::scan technical specification housing material: PVC, POM-C dimensions (diameter x lenght): 58 x 115 (without connection fitting) installation / mounting: submersed part numbers F-110-iscan: carrier for i::scan, for easy horizontal attachment F-120-iscan: carrier for i::scan, for easy vertical… -
flow cell for sensors (waste water)
For proper and easy installation of s::can sensors (pH::lyser, redo::lyser or condu::lyser) in waste water technical specification housing material: PVC dimensions : 177 x 95 x 111 mm Part Number: F-48-sensor Datasheet flow cell for sensors… -
single flow-cell (by-pass fitting), Pom-C (for i::scan)
for proper and easy flow-through installation of one i::scan automatic cleaning with autobrush for i::scan available (optional) technical specification housing material: POM-C dimensions (diameter x length): 70 x 86 process connection: G 1/4″, hose nozzle 7mm installation / mounting: flow cell operating temperature:… -
flow cell – for pathlength 100 mm
the flow cell is used for proper and easy flow-through installation of s::can spectrometer probes for applications without automatic cleaning OPL 100 mm technical specification housing material: POM-C dimensions (diameter x length): 60 x 160 mm weight (min.): 300 g process connection: G 1/4”, hose… -
Pressure mounting for i::scan in-pipe Installation (i::scan removal under pressure)
for proper and easy installation of one i::scan in a pressure pipe under pressure drilling of pipes possible (for PE, PVC, DCI, steel and AC pipes) the i::scan can be mounted and demounted under pressure without interuption of the water flow technical specification housing… -
flow cell for i::scan (waste water)
Flow cell for proper and easy flow-through installation of one i::scan in waste water application technical specifications housing material: PVC dimensions (lenght x width x height): 177 x 83 x 90 mm process connection: 1″ inside thread installation / mounting: flow cell recommended flow:… -
flow cell autobrush – for spectro::lyser pathlength 100 mm
for proper and easy flow-through installation of s::can spectrometer probes for applications with frequent, automatic cleaning cleaning of optical windows with rotating brush without demounting of spectrometer probes OPL 100 mm technical specification power supply: 12 VDC assembling: ex works… -
fixing adapter – stainless steel
supports the proper and easy installation of s::can systems quick mounting and demounting of InSitu installed s::can probes and sensors technical specification housing material: stainless steel weight (min.): 2.6 kg process connection: ID 50 mm part number: F-15 recommended accessories F-14-3 mounting… -
cleaning valve
supports automatic cleaning of measuring elements of s::can spectrometer probes, oxi::lyser, soli::lyser and ammo::lyser™ removal of fouling, sediments and clogging using compressed air or water version B-44-2 specially for use in comination with the s::can compressor technical specification cable length: 2.4 m (B-44);… -
cleaning brush
supports quick, easy and proper cleaning of optical windows of s::can spectrometer probes mechanical removal of persistent window fouling for pathlength 2, 5 or 15 mm technical specification dimensions (diameter x length): length 200 mm weight (min.): 1 g part number: B-60-1 for 2… -
cleaning agent
supports quick, easy and proper cleaning of optical windows of s::can spectrometer probes chemical removal of persistent window fouling very effective for grease and organic fouling technical specification weight (min.): 1.3 kg part number: B-61-1… -
flow cell autobrush – for spectro::lyser pathlength 35 mm
for proper and easy flow-through installation of s::can spectrometer probes for applications with frequent, automatic cleaning cleaning of optical windows with rotating brush without demounting of spectrometer probe OPL 35 mm technical specification power supply: 12 VDC assembling: ex works housing material: POM-C… -
s::can field case
stand-alone operation of s::can spectrometer probes no on-site power supply necessary for remote monitoring tasks without infrastructure technical specification power supply: 12 VDC nominal assembling: ex works housing material: PP dimensions (width x height x depth): 270 x 175 x 245 mm… -
weather shield for s::can terminals
for protection against severe weather conditions transparent cover plate available (optional) mounting prepared for con::cube or con::lyte for mounting on walls or railings incl. mounting device for diameter 40-63mm technical specification housing material: stainless steel dimensions (width x height… -
flow cell for four s::can physical probes
for proper and easy flow-through installation of condu::lyser, chlori::lyser, redo::lyser and pH::lyser for applications without automatic cleaning in drinking water technical specification housing material: POM-C dimensions (diameter x length): 106 x 103 weight (min.): 1.05 kg process connection: G 1/4″, hose nozzle 7mm… -
carrier s::can sensors
for proper and easy submersed installation of an s::can sensor sensor cable and pressure hose compatible mounting with pipe (AD 50 mm) technical specification housing material: PVC and stainless steel dimensions (diameter x length): 85 x 86 mm weight (min.): 300 g… -
i::scan flow cell for i::scan and up to 3 additional s::can probes
for proper and easy flow-through installation of one i::scan and up to three s::can physical probes automatic cleaning with autobrush for i::scan available (optional) technical specification housing material: POM-C dimensions (diameter x length): 106 x 103 weight (min.): 1 kg (without autobrush) process… -
extension cable for s::can sensors and s::can ISE probes
An extension of the sensor cable with IP 68 plug connection for flexible adaptation to local conditions. extension of sensor cable IP 68 plug connection flexible adjustment to local conditions technical specification cable length: 10, 20 or 30 m assembling: ex works… -
flow cell – for spectrometer probe (Waste Water)
A flow cell for proper and easy flow-through installation of one spectrometer probe in waste water applications technical specifications housing material: PVC dimensions (lenght x width x height): 177 x 83 x 90 mm process connection: 1″ inside thread installation / mounting: flow cell… -
reference electrode for ammo::lyser™
A durable and stable reference electrode for the ammo::lyser for measuring various parameters in wastewater, surface water or drinking water. long life time (typically 3 years) non-porous, solid state electrode smaller drift than conventional electrodes technical specification dimensions (diameter x length): 20 x 145 mm… -
potassium electrode for ammo::lyser™
An ion-selective electrode for measuring the potassium concentration with the ammo::lyser in waste water, surface water or drinking water. Technical specifications dimensions (diameter x length): 20 x 145 mm weight (min.): 100 g protection class: IP 68 (mounted in housing) part number: E-532-ise-K (for amm::lyser… -
pH electrode for ammo::lyser™
Ion-selective electrode for measuring the pH value with the ammo::lyser in waste water, surface water or drinking water. Technical specification part number: E-532-ise-pH (for ammo::lyser V1, spare part new) E-533-ise-pH (for ammo::lyser V2, spare part new)… -
flow cell for ammo::lyser (Waste Water)
A PVC flow-through fitting for measuring wastewater or surface water in the by-pass with an ammo::lyser. technical specification housing material: PVC dimensions : 177 x 83 x 108 mm Process connection: G 1″ internal Flow rate: < 40 l/min part Number: F-48-ammo … -
ammonium electrode for ammo::lyser™
An ion-selective electrode for measuring the ammonium concentration with the ammo::lyser in waste water, surface water or drinking water. Technical specification dimensions (diameter x length): 20 x 145 mm weight (min.): 100 g protection class: IP 68 (mounted in housing) part number: E-534-ise-NH4 (for ammo::lyser V1,… -
Inserts for spectrometer, stainless steel, sapphire windows
These inserts help to change the optical path length of V2 spectrometer probes and are made of stainless steel for permanent use. for adaption or repair the optical path length of s::can spectrometer probes stainless steel (ISO 1.4404), suitable for 35/5/2/1/0,5 mm OPL incl. sealings,… -
flow cell – for pathlengths from 0.5 mm to 35 mm
This 0.5 to 33mm flow cell is used for proper and easy flow-through installation of s::can spectrometer probes without automatic cleaning for proper and easy flow-through installation of s::can spectrometer probes for applications without automatic cleaning OPL 0.5 … 35 mm technical specification housing material: POM-C dimensions… -
multifunctional slide for pathlengths from 0.5 mm to 35 mm
for referencing of spectrometer probes for pathlength 0.5 – 35 mm for spectral measurement in laboratory technical specification dimensions (diameter x length): 60 x 100 mm (outside) installation / mounting: for 0.5 mm to 35 mm part number: E-421-1… -
multifunctional slide for pathlength 100 mm
for referencing of spectrometer probes for pathlength 100 mm for spectral measurement in laboratory technical specification dimensions (diameter x length): 60 x 160 mm (outside) installation / mounting: for 100 mm part number: E-421-2… -
carrier s::can spectrometer probe
for proper and easy submersed installation of s::can spectrometer probes probe cable and pressure hose compatible mounting with pipe (AD 50 mm) technical specification housing material: PVC and POM-C dimensions (diameter x length): 63 x 403 (for F-110-spectro); 63 x 510 mm (for F-120-spectro)… -
flow cell – for pathlength 100 mm
for proper and easy flow-through installation of s::can spectrometer probes for applications without automatic cleaning OPL 100 mm technical specification housing material: POM-C dimensions (diameter x length): 74 x 196 mm weight (min.): 800 g process connection: G 1/2”, hose nozzle 12mm installation /… -
extension cable for s::can spectrometer probes
extension of spectrometer probe cable IP 67 plug connection flexible adjustment to local conditions technical specification cable length: 10, 20 or 30 m assembling: ex works housing material: jacket: PU protection class: IP 67 interface connection to s::can spectrometric probes: MIL 10P, IP…